Low MOQ for Zst Types Glass Bulb Fire Sprinkler – Special response sprinkler bulbs (short type) – Zhurong Detail:

Size(mm) Temperature Rating(℃/°F) Color
A 3.8 57℃ / 135°F orange
B 2.02 68℃ / 155°F red
C <4.5 79℃ / 175°F yellow
D 5±0.1 93℃ / 200°F green
d1 5.1±0.2 141℃ / 286°F blue
d2 5.1±0.3
L 19.8±0.5
l1 16±0.4
l2 15.8±0.4
Glass bulb load(N) Average Cursh load(X) 4000
lower Tolerance Limit(TL) ≥2000
Maximum clamping torque 8.0 N·cm
Response time index(m*s)0.5 80<RTI≤350

 

Although it is smaller, each product is subject to strict factory inspection before leaving the factory, including appearance, size, static action temperature and crushing load test.
During the static action temperature test, the test ambient temperature is (20 ± 5) ℃, and the test is carried out in liquid bath. Water bath (distilled water is preferred) shall be adopted for glass bulbs with nominal operating temperature not higher than 79 ℃, and oil bath (oil products suitable for nominal operating temperature) shall be adopted for glass bulbs with nominal operating temperature higher than 79 ℃. The temperature of the test liquid bath shall be uniform, the temperature deviation in the test area shall not exceed 0.5 ℃, and the temperature measurement accuracy shall not be less than ± 0.1 ℃.
Place the glass bulb sample vertically in the liquid bath. The distance between the center of the glass bulb and the liquid level is not less than (40 ± 5) mm. Raise the temperature from room temperature to (20 ± 2) ℃ lower than the nominal operating temperature at a heating rate of not more than 20 ℃ / min. after holding for 10 minutes, raise the temperature at a rate of 0.4 ℃ / min ~ 0.6 ℃ / min until all the samples are broken. Record the operating temperature of each sample, Judge whether the test results exceed the following temperature range:
X ±(0.035X + 0.62)
X — Nominal operating temperature, unit: Celsius (℃).


Product detail pictures:

Low MOQ for Zst Types Glass Bulb Fire Sprinkler – Special response sprinkler bulbs (short type) – Zhurong detail pictures

Low MOQ for Zst Types Glass Bulb Fire Sprinkler – Special response sprinkler bulbs (short type) – Zhurong detail pictures

Low MOQ for Zst Types Glass Bulb Fire Sprinkler – Special response sprinkler bulbs (short type) – Zhurong detail pictures

Low MOQ for Zst Types Glass Bulb Fire Sprinkler – Special response sprinkler bulbs (short type) – Zhurong detail pictures

Low MOQ for Zst Types Glass Bulb Fire Sprinkler – Special response sprinkler bulbs (short type) – Zhurong detail pictures

Low MOQ for Zst Types Glass Bulb Fire Sprinkler – Special response sprinkler bulbs (short type) – Zhurong detail pictures


Related Product Guide:

We usually believe that one's character decides products' high quality, the details decides products' excellent ,with the REALISTIC,EFFICIENT AND INNOVATIVE staff spirit for Low MOQ for Zst Types Glass Bulb Fire Sprinkler – Special response sprinkler bulbs (short type) – Zhurong , The product will supply to all over the world, such as: Australia, Kuala Lumpur, Comoros, We can give our clients absolute advantages in product quality and cost control, and we have full range of molds from up to one hundred of factories. As product updating fast, we succeed in developing many high quality products for our clients and get high reputation.
  • This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Tony from United Arab emirates - 2017.06.16 18:23
    It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Molly from Iran - 2017.05.21 12:31
    Write your message here and send it to us