We not only will try our greatest to supply outstanding services to every shopper, but also are ready to receive any suggestion offered by our buyers for Open Fire Sprinkler, Fire Sprinkler Dropper, Zstx115-57℃, For further queries or should you have any question regarding our products, please do not hesitate to contact us.
Low MOQ for Zst Types Glass Bulb Fire Sprinkler – Special Response Fire Sprinkler Bulb 5mm Thermo Bulb Temperature sensitive glass bulb fire ampoules used in the fire sprinkler – Zhurong Detail:

asfafa

Size(mm) Temperature Rating(℃/°F) Color
A 3.8 57℃ / 135°F orange
B 2.02 68℃ / 155°F red
C <4.5 79℃ / 175°F yellow
D 5±0.1 93℃ / 200°F green
d1 5.3±0.2 141℃ / 286°F blue
d2 5.3±0.3  
L 24.5±0.5  
l1 20±0.4  
l2 19.8±0.4  
Glass bulb load(N) Average Cursh load(X) 4000
lower Tolerance Limit(TL) ≥2000
Maximum clamping torque 8.0 N·cm
Response time index(m*s)0.5 80<RTI≤350

1.The glass ball sprinkler head is a key thermal sensitive element in the Automatic Sprinkler System. The glass ball is filled with organic solutions with different expansion coefficients. After thermal expansion at different temperatures, the glass ball is broken, and the water in the pipeline is sprayed upward, downward, or to the side of the splash tray with different designs, so as to achieve the purpose of automatic sprinkler. It is applicable to the pipe network of automatic sprinkler system in factories, hospitals, schools, airports, shopping malls, hotels, restaurants, entertainment places and basements where the ambient temperature is 4 ° C~70 ° C.

2.Working principle:The glass ball body of the glass ball sprinkler is filled with organic solution with high coefficient of thermal expansion. At normal temperature, the shell of the ball can bear a certain supporting force to ensure the sealing performance of the sprinkler. In case of fire, the organic solution will expand as the temperature rises until the glass body is broken, and the ball seat and sealing parts will be washed off by the water after losing their support, so as to start spraying water to extinguish the fire.

3. Structural characteristics Closed glass ball sprinkler is composed of sprinkler head, fire glass ball, splash tray, ball seat and seal, set screw, etc. After passing the full inspection of 3MPa sealing test and the qualification assessment of sampling inspection items, the set screw is solidified with adhesive and supplied to the market for regular installation. After installation, it is not allowed to re assemble, disassemble and change.

1. The special wrench provided by the manufacturer must be used, and other tools shall not be used for installation;

2. Before installation, when separating the nozzle (housing and housing base), gently unscrew it along the thread and put it in properly
In the foam box, it is not allowed to use brute force to force separation, otherwise the cover and cover seat may fall off;
3. During installation, wrap enough raw material tape around the thread of the nozzle, and then screw the nozzle into the pipe fittings gently by hand
In the thread, screw on the nozzle with a special wrench. The gap between the nozzle base and the pipe fittings should be 2-3MM
The base of the nozzle can be closely contacted with the pipe fittings, otherwise it is easy to cause deformation and water leakage of the nozzle frame;
3. The fusible alloy sheet of the nozzle and the nozzle frame are relatively fragile, so the wrench must not be collided and easily fused during installation

My company’s main fire products are: sprinkler head, spray head, water curtain sprinkler head, foam sprinkler head, early suppression quick response sprinkler head, quick response sprinkler head, glass ball sprinkler head, hidden sprinkler head, fusible alloy sprinkler head, and so on.

Support ODM/OEM customization, according to customer requirements.

20221014163001
20221014163149

1.Free sample
2.Keep you updated with our production schedule to ensure you know each process
3.Shipment sample for checking before shipping
4.Have a perfect after-sales service system
5.Long term cooperation, price can be discounted

1.Are you a manufacturer or trader?
We are professional manufacturer and trader for more than 10 years, you are welcomed to visit us.
2.How can I get your catalog?
You can contact via e-mail, we’ll share our catalog with you.
3.How can I get the price?
Contact us and tell us your detail requirements, we’ll provide accurate price accordingly.
4.How can I get sample?
If you take our design, the sample is free and you pay shipping cost. If custom your design sample, you need to pay sampling cost.
5.Can I have different designs?
Yes, you can have different designs, you can choose from our design, or send us your designs for custom.
6.Can you custom packing?
Yes.

The products will pass strict inspection and screening before leaving the factory to eliminate the output of defective products

cdscs1
cdscs2
cdscs4
cdscs5

We have many imported processing equipment to support the manufacturing of various fire sprinklers, hardware and plastics.

csdvf1
csdvf2
csdvf3
csdvf4
csdvf5
csdvf6
csdvf7
csdvf8
csdvf9
20221017093048
20221017093056


Product detail pictures:

Low MOQ for Zst Types Glass Bulb Fire Sprinkler – Special Response Fire Sprinkler Bulb 5mm Thermo Bulb Temperature sensitive glass bulb fire ampoules used in the fire sprinkler – Zhurong detail pictures

Low MOQ for Zst Types Glass Bulb Fire Sprinkler – Special Response Fire Sprinkler Bulb 5mm Thermo Bulb Temperature sensitive glass bulb fire ampoules used in the fire sprinkler – Zhurong detail pictures

Low MOQ for Zst Types Glass Bulb Fire Sprinkler – Special Response Fire Sprinkler Bulb 5mm Thermo Bulb Temperature sensitive glass bulb fire ampoules used in the fire sprinkler – Zhurong detail pictures

Low MOQ for Zst Types Glass Bulb Fire Sprinkler – Special Response Fire Sprinkler Bulb 5mm Thermo Bulb Temperature sensitive glass bulb fire ampoules used in the fire sprinkler – Zhurong detail pictures

Low MOQ for Zst Types Glass Bulb Fire Sprinkler – Special Response Fire Sprinkler Bulb 5mm Thermo Bulb Temperature sensitive glass bulb fire ampoules used in the fire sprinkler – Zhurong detail pictures


Related Product Guide:

We always get the job done to be a tangible staff to ensure that we can easily offer you the best high-quality and the greatest value for Low MOQ for Zst Types Glass Bulb Fire Sprinkler – Special Response Fire Sprinkler Bulb 5mm Thermo Bulb Temperature sensitive glass bulb fire ampoules used in the fire sprinkler – Zhurong , The product will supply to all over the world, such as: Myanmar, Austria, Russia, Business philosophy: Take the customer as the Center, take the quality as the life, integrity, responsibility, focus, innovation.We will provide professional, quality in return for the trust of customers, with most major global suppliers,all of our employees will work together and move forward together.
  • Hope that the company could stick to the enterprise spirit of Quality, Efficiency, Innovation and Integrity, it will be better and better in the future.
    5 Stars By Alberta from Bahrain - 2018.05.13 17:00
    The manufacturer gave us a big discount under the premise of ensuring the quality of products, thank you very much, we will select this company again.
    5 Stars By Jean Ascher from United Arab emirates - 2018.09.08 17:09
    Write your message here and send it to us