Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We have been also specializing in improving the things administration and QC system to ensure that we could preserve terrific gain within the fiercely-competitive company for Fire Fighting Equipment, Spray Sprinkler, Fire Sprinkler For Automatic Fire Extinguisher, It is our great honor to meet your demands.We sincerely hope we can cooperate with you in the near future.
Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong Detail:

Model ESFR-202/68℃ P ESFR-202/68℃ U ESFR-202/74℃ P ESFR-202/74℃ U ESFR-242/74℃ P ESFR-242/74℃ U ESFR-323/74℃ P ESFR-323/74℃ U ESFR-363/74℃ P ESFR-363/74℃ U
Mounting Pendent Upright Pendent Upright Pendent Upright Pendent Upright Pendent Upright
Flow Characteristics 202 202 242 323 363
Thread Size R₂ 3/4 R₂ 1
Nominal action temperature 68℃ 74℃
Nominal Working Pressure 1.2MPa
Factory test pressure 3.4MPa

Background – History

In the 1980s, early suppression, fast response (ESFR) sprinkler systems were developed as an alternative to in-rack systems. They were designed to actually suppress or extinguish the fire, while conventional sprinklers can only control fires, therefore eliminating the need for extinguishment by firefighters.
How do they work? ESFR sprinklers are designed to release 2-3 times the amount of water of conventional sprinkler heads and to emit larger droplets of water, which in turn have a greater momentum than droplets emitted from conventional heads. As a result, more water and a greater share of the water reaches the fire allowing the flames to be extinguished.

Application

In general, ESFR systems can be used in warehouses with storage that do not exceed 40 feet in overall height, and with a ceiling height of less than 45 feet. And there are sprinkler system protection schemes that will allow storage above those heights. These may include in-rack sprinklers or a combination of ESFR with in-rack sprinklers.
ESFR systems are designed to protect a wide array of commodities. This provides more flexibility in warehouse operations when compared to control mode (conventional) sprinkler systems, which are designed to protect only the commodities that were stored at the time of system installation. If the storage situation requires in-rack sprinklers to be installed to the existing control mode systems of a warehouse building, often building owners prefer to change over to ESFR, simply because then there is no need to worry about damaging in-rack sprinkler heads during normal storage operations. Additionally, in-rack sprinklers have to be removed and sometimes replaced with each new tenant, since the tenants own the racks. Therefore, converting to an ESFR system is at times more cost-effective in the long run.


Product detail pictures:

Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong detail pictures

Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong detail pictures

Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong detail pictures

Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong detail pictures

Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong detail pictures

Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong detail pictures


Related Product Guide:

Our business promises all users of the first-class items and the most satisfying post-sale company. We warmly welcome our regular and new prospects to join us for Good User Reputation for Horizontal And Vertical Sidewall Nozzles - Fusible alloy/Sprinkler bulb ESFR sprinkler heads – Zhurong , The product will supply to all over the world, such as: Palestine, South Africa, New Zealand, More than 26 years, Professional companies from all over the world take us as their long-term and stable partners. We are keeping durable business relationship with more than 200 wholesalers in Japan, Korea, USA, UK, Germany, Canada, France, Italian, Poland, South Africa, Ghana, Nigeria etc.
  • It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Arlene from Florida - 2018.09.16 11:31
    This is a very professional and honest Chinese supplier, from now on we fell in love with the Chinese manufacturing.
    5 Stars By Mary from Lisbon - 2018.07.27 12:26
    Write your message here and send it to us