We believe that long time period partnership is a result of top of the range, value added services, rich expertise and personal contact for Automatic Sprinkler Systems, Hidden Type Sprinkler, Standard Response Fire Sprinkler, We'll do our greatest to fulfill your specifications and are sincerely searching ahead to developing mutual helpful small business marriage with you!
Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong Detail:

Size(mm) Temperature Rating (℃/°F) Color
A 2.4 68℃ / 155°F red
B 1.5 79℃ / 175°F yellow
C <4.2 93℃ / 200°F green
D 3±0.1 141℃ / 286°F blue
d1 3.5±0.4
d2 3.5±0.3
L 23±0.5
l1 20±0.4
l2 19.8±0.4
Glass bulb load(N) Average Cursh load(X) 3600
lower Tolerance Limit(TL) ≥1600
aximum clamping torque 6.5 N·cm
Response time index(m*s)0.5 RTI≤50

kjhgoiuhjkl

The printed text on 3mm sprinkler bulb is “ZJCY”. Compared with 5mm sprinkler bulb, its response will be faster, RTI ≤ 50, where RTI is a coefficient measured under standard conditions to measure the sensitivity of sprinkler bulb. Expressions:RTI= τ u ½

Where: RTI – response time coefficient, unit (m * s) ½;
τ- Response time constant, in S;
u – gas flow rate, unit: M / s
The quality of the sprinkler bulb fully complies with the Chinese national standard GB18428-2010. The diameter of the sprinkler bulb is 3mm, and the deviation from the nominal diameter will not exceed ± 0.1mm; Its length is 23mm and the deviation from the nominal length will not exceed 0.5mm.
The average crushing load of the sprinkler bulb is 3600n. During the test, the sprinkler bulb will be fixed between the supporting elements in an appropriate way, and the supporting elements are made of steel. The Rockwell hardness is (44 ± 6) HRC, which meets the corresponding service requirements. Then, apply a uniform load along the axis of the sprinkler bulb until the sprinkler bulb bursts, and the rate of load increase is (250 ± 25) n / s. The maximum deviation of the equipment used to measure the crushing load shall not exceed ± 1% of the measured value. Use multiple groups of measured data to calculate the average value and standard deviation of the crushing load and judge whether the results meet the specified standards.


Product detail pictures:

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures

Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong detail pictures


Related Product Guide:

We believe that prolonged expression partnership is really a result of top of the range, value added support, rich encounter and personal contact for Factory For Ffire Glass Bulb Sprinkler - 3mm Fast response sprinkler bulbs – Zhurong , The product will supply to all over the world, such as: Los Angeles, Morocco, Uruguay, We warmly welcome you to come to visit us personally. We hope to establish a long-term friendship based on equality and mutual benefit. If you want to get in touch with us, please do not hesitate to call. We will be your best choice.
  • Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
    5 Stars By Nicci Hackner from Hungary - 2017.03.07 13:42
    The company can keep up with the changes in this industry market, product updates fast and the price is cheap, this is our second cooperation, it's good.
    5 Stars By Constance from Jamaica - 2017.03.28 12:22
    Write your message here and send it to us