To continuously increase the administration process by virtue of the rule of sincerely, good religion and excellent are the base of company development, we commonly absorb the essence of linked goods internationally, and continually build new solutions to fulfill the requires of shoppers for 3mm 93℃, Middle Angle Sprinkler, Concealed Type Sprinkler, We are confident to make great achievements in the future. We are looking forward to becoming one of your most reliable suppliers.
Factory Cheap Hot 5mm 79℃ Bulb - 5mm Special response sprinkler bulbs – Zhurong Detail:

Size(mm) Temperature Rating(℃/°F) Color
A 3.8 57℃ / 135°F orange
B 2.02 68℃ / 155°F red
C <4.5 79℃ / 175°F yellow
D 5±0.1 93℃ / 200°F green
d1 5.3±0.2 141℃ / 286°F blue
d2 5.3±0.3
L 24.5±0.5
l1 20±0.4
l2 19.8±0.4
Glass bulb load(N) Average Cursh load(X) 4000
lower Tolerance Limit(TL) ≥2000
Maximum clamping torque 8.0 N·cm
Response time index(m*s)0.5 80<RTI≤350

jgf

A glass sprinkler bulb is the most reliable and economic device used to actuate a fire sprinkler head. The frangible bulb is simple to use, comprising a small thermo bulb made of glass containing a chemical liquid that will expand rapidly when exposed to rising temperatures, bursting the glass fire bulb at an accurately pre-determined temperature, thereby activating the sprinkler.

Precision engineering and exhaustive quality control in every stage of production ensures that the 3 most critical bulb characteristics are achieved.
Uniform and consistent size
High mechanical strength
Highly accurate operation temperature within
tight tolerances
Consistent RTI values
The entire manufacturing process carries certification to the Quality Standard ISO9001:2015,

This product may also be referred to as:

Frangible Bulbs
Glass Sprinkler Bulbs
Thermo Bulbs

Product Description

Sprinkler bulbs are thermally actuated release elements for automatic sprinklers, smoke vents, fire dampers and other release devices. A hermetically sealed liquid in the glass bulbs expands with rising temperatures breaking the bulbs into small fragments at a predetermined release tem- perature. The bone shape design of Sprinkler bulbs combined with the special liquid are decisive factors for the outstanding thermal response perfor- mance and strength of the glass bulbs.

Sprinkler Bulbs
With their unique bone shape design rein- forced ends are used to absorb loads from the mounting supports and to introduce these axially into a shaft of reduced diameter thus avoiding unfavourable shearing and bending stresses in the glass. Furthermore the out- standing tension condition allows a low mass structure, which, combined with the special filling liquid, provides very low Response Times.

Response Time Index (RTI)
The Response Time Index is a calculated figure describing the actual operating time of a glass bulb mounted in a sprinkler or other devices in given standard conditions. The RTI is an indication of the thermal sensitivity of the glass bulb. The lower the value of the RTI, the faster the response time of the bulb. sprinkler bulbs are able to meet any RTI requirements the user may have by combining diff erent actuating liquids with various bulb diameters.
Standard Response Applications RTI>80
Special Response Applications 80>RTI>50
Fast, Super Fast and Ultra Fast-Response Applications RTI<50

Features

Design Flexibility
Its own drawn glass tubes. That offers huge flexibility for glass bulbs with different lengths, aspect ratios and strength / RTI specications towards customer‘s demand.
Operating Temperatures
The differnet colours of the fluid in the Sprinkler Bulbs signify differnet operating temperatures. The bulb colouring complies with all national and international standards for colour/temperature ratings


Product detail pictures:

Factory Cheap Hot 5mm 79℃ Bulb - 5mm Special response sprinkler bulbs – Zhurong detail pictures

Factory Cheap Hot 5mm 79℃ Bulb - 5mm Special response sprinkler bulbs – Zhurong detail pictures

Factory Cheap Hot 5mm 79℃ Bulb - 5mm Special response sprinkler bulbs – Zhurong detail pictures

Factory Cheap Hot 5mm 79℃ Bulb - 5mm Special response sprinkler bulbs – Zhurong detail pictures

Factory Cheap Hot 5mm 79℃ Bulb - 5mm Special response sprinkler bulbs – Zhurong detail pictures


Related Product Guide:

We goal to see good quality disfigurement within the manufacturing and provide the most effective support to domestic and overseas shoppers wholeheartedly for Factory Cheap Hot 5mm 79℃ Bulb - 5mm Special response sprinkler bulbs – Zhurong , The product will supply to all over the world, such as: Botswana, Las Vegas, Dubai, By integrating manufacturing with foreign trade sectors, we can present total customer solutions by guaranteeing the delivery of right merchandise to the right place at the right time, which is supported by our abundant experiences, powerful production capability, consistent quality, diversified products and the control of the industry trend as well as our maturity before and after sales services. We'd like to share our ideas with you and welcome your comments and questions.
  • The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Sally from Istanbul - 2017.12.19 11:10
    As a veteran of this industry, we can say that the company can be a leader in the industry, select them is right.
    5 Stars By Raymond from Brisbane - 2018.06.18 17:25
    Write your message here and send it to us